PM310H/PM210H High-Precision AC/DC Electrical Parameter Meter

PM310H Class 0.2 / PM210H Class 0.5 high-current harmonic; AC/DC, DF, harmonic; IEC61000-3-2:2020

PM310H/PM210H High-Precision AC/DC Electrical Parameter Meter

Introduction

The PM310H/PM210H electrical parameter test system uses digital sampling technology for waveform quantization and analysis. It is a new-generation intelligent product. PM310H is the Class 0.2 high-precision model: it uses phase-locked loop (PLL) sampling for power-frequency signals for high-precision harmonic analysis, meets IEC61000-3-2:2020 and EN61000-3-2 limit clauses, supports DF testing, and performs compliance judgment and test reporting per standard for harmonics and phase angle. PM210H is the Class 0.5 high-current harmonic analysis model: it uses PLL synchronization to accurately calculate voltage and current THD and individual harmonic values. Both have RMS and DC measurement modes, high intelligence, ease of use and good stability, and are widely used for electrical performance testing of motors, household appliances and lighting products.

Technology & Features

  • PM310H: Class 0.2 accuracy; PM210H: Class 0.5, high-current harmonic analysis
  • AC/DC measurement, RMS and DC modes, PLL sampling/synchronization
  • Meets IEC61000-3-2:2020, EN61000-3-2; DF testing supported
  • PM310H: compliance judgment and test report for harmonics and phase angle per standard
  • High intelligence, ease of use, good stability and accuracy

Applications

Widely used for electrical performance testing of motors, household appliances and lighting products; suitable for harmonic and DF compliance testing, high-current harmonic analysis, and laboratory/production line quality control.

Specifications

ModelPM310HPM210H
DisplayLCDLCD
OperationTouch screenTouch screen
Measurement parametersInput V, I, P, PF, DF, freq.(Hz), total harmonic, 0–50th order, start/peak/cutoff phase angleInput V, I, P, PF, DF, freq.(Hz), total harmonic, 0–50th order, start/peak/cutoff phase angle
Basic accuracy±(0.1% rdg+0.1% FS+1 dgt), Class 0.2±(0.2% rdg+0.2% FS+1 dgt), Class 0.5
Voltage rangeDC, AC: 0.5V–600VDC, AC: 0.5V–600V
Current rangeDC, AC: 5mA–20ADC, AC: 5mA–20A (high-current harmonic)
Frequency rangeDC, 0.1Hz–5kHzDC, 0.1Hz–5kHz
Harmonic measurementStandard, IEC61000-4-7Standard, IEC61000-4-7
THD analysis order1–501–50
CommunicationRS232 (std)/RS485 (opt)RS232 (std)/RS485 (opt)
PC softwarePM310H IEC61000-3-2PM210H